Rexroth Hydraulic Piston A2fe80 90 107 125 Motor for Construction

Rexroth Hydraulic Piston A2fe80 90 107 125 Motor for Construction

CZPT  CZPT piston A2fe80/90/107/125 Motor   for CZPT

Brueninghaus Hydromatik CZPT A2FE motor
 
CZPT set motor A2FE28, A2FE32, A2FE45, A2FE56, A2FE63, A2FE80, A2FE90, A2FE107, A2FE125, A2FE160, A2FE180,
A2FE250, A2FE355

Description  

Open and shut circuits
Series 61 and sixty
Stress:
Dimensions 28 to180 Nominal force 5800 psi (four hundred bar)/ Peak force 6500 psi (450 bar)
Dimensions 250 to 355 Nominal pressure 5100 psi (350 bar)/ Peak pressure 5800 psi (400 bar)
 
The A2FE fixed plug-in motor with axial tapered piston rotary group of bent-axis layout, for hydrostatic drives in open and closed circuits
-Much-reaching integration in mechanical gearbox because of to recessed mounting flange situated in the heart of the case (really space-conserving design)
-The output speed is dependent on the movement of the pump and the displacement of the motor.
-The output torque increases with the force differential between the substantial-stress and the reduced-force facet.
-Little dimensions.
-High whole effectiveness.
-Comprehensive device, ready-assembled and examined.
-Effortless to put in, basically plug into the mechanical gearbox.
-No configuration requirements to be observed when installing.
 
Complex Data 
Desk of values (theoretical values, without effectiveness and tolerances values rounded)

CZPT A2FE motor A2FE28 A2FE32 A2FE45 A2FE56 A2FE63 A2FE80  
Displacement Vg cm3 28.one 32 45.6 56.1 63 80.4  
Speed optimum nnom rpm 6300 6300 5600 5000 5000 4500  
nmax2) rpm 6900 6900 6200 5500 5500 5000  
Input flow Vg qV L/min 177 202 255 281 315 362  
Torque at Vg and Dp = 350 bar T Nm 157 178 254 313 351  
Dp = four hundred bar T Nm 179 204 290 357 401  
Rotary stiffness c kNm/ rad two.ninety three 3.12 4.18 five.ninety four 6.25 8.73  
Second of inertia JGR  kgm2 .0012 .0012 .0571 .0042 .0042 .0072  
Maximum angular a rad/s2 6500 6500 14600 7500 7500 6000  
Circumstance quantity V  L .2 .two .33 .45 .45 .fifty five  
Mass (approx.) m kg 10.five 10.5 15 18 19 23  
Dimensions A2FE90 A2FE107 A2FE125 A2FE160 A2FE180 A2FE250 A2FE355
Displacement Vg cm3 90 106.7 125 one hundred sixty.4 one hundred eighty 250 355
Pace optimum nnom rpm 4500 4000 4000 3600 3600 2700 2240
nmax2) rpm 5000 4400 4400 4000 4000
Enter stream qV L/min 405 427 500 577 648 675 795
Torque at Vg Dp = 350 bar T 501 594 696 893 1003 1393 1978
Dp = four hundred bar T 573 679 796 1571 1146
Rotary stiffness c kNm/rad nine.14 11.two eleven.nine 17.4 18.2 seventy three.1 ninety six.one
Second of inertia JGR kgm2 .0072 .0116 .0116 .571 .571 .061 .102
Maximum angular a rad/s2 6000 4500 4500 3500 3500 ten thousand 8300
Circumstance quantity V L .fifty five .eight .eight 1.1 1.1 2.five three.5
Mass (approx.) m kg 25 34 36 47 48 82 one hundred ten

CZPT fluid
Just before starting up project plHangCZPT, remember to refer to our data sheets RE 95710 (mineral oil), RE 95711 (environmentally suitable hydraulic fluids) and RE 95712 (HFD hydraulic fluids) and RE 95713 (HFA, HFB, HFC hydraulic fluids) for comprehensive info relating to the decision of hydraulic fluid and software situations. The plug-in motor A2FE is not suited for operation with HFA hydraulic fluid. If HFB, HFC or HFD or environmentally satisfactory hydraulic fluids are employed, the restrictions regarding specialized information or other seals should be observed.
Particulars concerning the option of hydraulic fluid
The appropriate decision of hydraulic fluid demands knowledge of the working temperature in relation to the ambient temperature: in a closed circuit, the circuit temperature, in an open circuit, the reservoir temperature. The hydraulic fluid should be decided on so that the running viscosity in the functioning temperature selection is in the optimum selection (νopt), see shaded region of the choice diagram. We advised that the larger viscosity class be selected in each case. Instance: At an ambient temperature of X °C, an operating temperature of sixty °C is established in the circuit. In the optimum running viscosity variety (νopt., shaded spot) this corresponds to the viscosity courses VG forty six or VG sixty eight to be chosen: VG 68.
Observe: The scenario drain temperature, which is influenced by pressure and speed, can be larger than the circuit temperature or reservoir temperature. At no point of the component might the temperature be larger than 115 °C. The temperature variation specified below is to be taken into account when deciding the viscosity in the bearing. If the above problems can not be maintained owing to severe functioning parameters, we recommend the use of a flushing and increase force valve.
Shaft seal
Permissible stress loading the support existence of the shaft seal is influenced by the velocity of the axial piston unit and the situation drain force (circumstance strain). The suggest differential strain of 2 bar amongst the circumstance and the ambient strain may possibly not be enduringly exceeded at normal working temperature. For a larger differential strain at reduced speed, see diagram. Momentary pressure spikes (t < 0.1 s) of up to 10 bar are permitted. The service life of the shaft seal decreases with an increase in the frequency of pressure spikes.

 