Advanced Test Resources Synchronous Reluctance AC Pm Motor

Advanced Test Resources Synchronous Reluctance AC Pm Motor

Advanced Examination CZPTs Synchronous Reluctance AC PM Motor

Item Attribute
1.Appropriate for the 6000rpm higher pace
2.High electrical power & high torque
3.Higher efficiency
4.Tiny measurement
5.Reduced noise minimal vibration
six.Patented cooling structure
seven.Effortless servicing and prolonged existence time
eight.Productive Coaxial Fan

Requirements
Product variety: SRPM205L8XO37B
Voltage: 380V AC
Rated Power: 37KW
Rate Torque : fifty eight.9N.m
Working velocity: 6000rpm
Efficiency: ninety six.2%
Isolation: H/F
Pole Number: 8
Cooling Approach: Air Cooling 
Situation Signal: Resolver (optional)
Set up Approach: B5/B35
Fat:≤47KG

Software
Followers,Pumps,Compressors

Other Versions you will be interested in:

Motor sort Voltage
(V AC)
Rated energy
(kW)
Rated torque (N.m) Rated velocity
(rpm)
Effectiveness
(%)
Support Factor Insulation Ingress safety Pole Variety Bodyweight
(kg)
Cooling Technique Placement Signal  Installation Method
SRPM205L8XF18.five 380 eighteen.five 35.3 5000 ninety six one.2 H/F IP54 8 38 Air Cooling Resolver B35
SRPM205L8XF22 380 22 36.3 5800 ninety six 1.two H/F IP54 8 41 Air Cooling Resolver B35
SRPM205L8XF30 380 30 forty nine.four 5800 ninety six.1 one.two H/F IP54 eight 46 Air Cooling Resolver B35
SRPM205L8XF37 380 37 fifty five 6500 96.three one.two H/F IP54 eight fifty Air Cooling Resolver B35
SRPM205L8XF45 380 forty five sixty six.1 6500 ninety six.3 one.2 H/F IP54 eight 76 Air Cooling Resolver B35
SRPM205L8XF55 380 fifty five 80.8 6500 96.three one.2 H/F IP54 8 85 Air Cooling Resolver B35
SRPM205L8XF75 380 75 a hundred and ten 6500 96.5 one.two H/F IP54 eight 97 Air Cooling Resolver B35
SRPM314L8X135 380 135 253 5100 ninety seven.five one.two H/F eight Refrigerant Resolver

FAQ
1. Can performanent magnet synchronous motor be used as generator? 

No. Long lasting magnet synchronous motor is totally diverse from generator. It is only ac motor that outputs speed and torque to push electric units, but not energy supply. 
 
two. Why can not directly use 3 section ac offer voltage to begin long term magnet synchronous motor? 
Becuase rotor is with big innertia, and magetic files spins so fast that static rotor has no way to spin with magetic filed. 
 
three. Any specific technological ask for on this motor’s VFD driver? And Do you have this kind of driver? 
Permanent magnet synchronous motor’s driver need to be vector control VFD with unique internal software program, this kind of as Siemens 6SE70 collection, Yakawa CR5 series, ABB ACS800 series, Mitsubishi A740 sequence, B&R P84 and P74 collection, and so on.. Sure, our MH300 collection VFD matches with this motor. 
 
four. Is there any protective actions to protect everlasting magnet rotor from failure? 
Yes, each long term magnet rotor passes corrossion resistance, consistency, substantial temperature demagnetization check, linear demagnetization examination, and so on. Its demagnetization index is in 2%. But if operating environment is critical oxiditive corrosion, kindly suggest for larger protection stage. 
 
five. The place is this everlasting magnet synchronous motor normally used to? 
This long lasting magnet synchronous motor is generally employed to variable frequency pace scenario.
 

Advanced Test Resources Synchronous Reluctance AC Pm Motor

Tags: